[email protected]

Alfa Laval - Gasketed plate-and-frame heat exchangers

Our Gasketed plate heat exchangers are optimizing heat transfer by large surfaces of corrugated plates drawing heat from one gas or liquid to the other. The high efficiency and an outstanding reliability in a compact design, offers an investment with the most attractive CTO over the product life time. Alfa Laval Packinox for paraffin dehydrogenation - Alfa Alfa Laval Packinox Standard Combined Feed/Effluent Heat Exchangers began service in paraffin dehydrogenation units in the mid-1990s. They currently operate in paraffin dehydrogenation units demanding duty between 15 MW and 65 MW, in dimensions including lengths ranging from 10m to 15m, diameters between 2m and 3m, and total weight of 30 to 85 tons.

Chemical, Process and Asset Integrity - TOSL Engineering Ltd.

Depending on our customer needs, our global partner, Alfa Laval, a leading provider of plate heat exchangers all characterized by its compact design and high thermal efficiency, is able to provide a complete range of fully optimized plate heat exchanger designs, sizes and applications. China High Quality B5T Brazed Plate Heat Exchanger Plate Heat Exchanger for Paraffin Emulsion. It is the plate heat exchanger used the NT150L plate. Read More. Hygienic Stainless Steel Apv T4 H12 H17 N25 N35 Plate Heat Exchanger for Milk Pasteuriz The food grade plate heat exchanger is assembled by stainless steel plate and frame, and is pasteurized. It can be used in the food industry. Cipriani Heat Exchangers - ProductsThe cost of a Cipriani plate heat exchanger varies based on the characteristics of the product. No one solution is equal to another, thanks to the broad configuration possibilities. With our Software, you can customise every aspect of your product to obtain, at the end of the process, the effective cost of your heat exchanger.

Filters for Protection of Heat Exchangers - DANGO

Filters for Protection of Heat Exchangers The process heat generated in plants is dissipated with plate and tube heat exchangers. Impurities can reduce the efficiency of a heat exchanger so much that it can overheat in the end, which makes cleaning of the heat exchanger inevitable. Low temperature paraffin phase change emulsions Dec 01, 2010 · It is composed of a storage tank with a volume of 25 l, a thermostat Lauda RE 310 with a heating output of 2.25 kW and a cooling output between 0.27 and 0.50 kW in a temperature range from 40 °C to 200 °C, a plate heat exchanger Cetepac 31010 having a volume of 0.45 l and a heat exchange area of 0.24 m 2, and a Laing heating pump S4-36/360 G with a capacity of up to 4 m 3 /h. MINIMIZING CRUDE OIL FOULING BY MODIFYING THE (WAT) leading to paraffin wax crystallization at the plate wall of the heat exchanger. The WAT depends on the crude oil composition and also on the determination method. Elsharkawy et al. (2000) used differential scanning calorimetry to determine the WAT for different crude oils and reported values rangingfrom 32 to 38°C. The

Margarine plant systems - Alfa Laval - heat transfer

Centrifugal pumps Plate heat exchanger Mixes emulsifiers, colouring and flavouring with oil Emulsifier blending Mixes the water phase and the oil phase Emulsion preparation Transfers the oil phase and emulsifier from the storage tank to the weighing system and onward to the plate heat exchanger Heats oil to 70°C Oil phase and emulsifier preparation NEW DALWORTH ASPHALT SYSTEMSThis unit can be custom built to your specifications with tank & line heat, VFD's and Heat Exchanger. It can be built on a cart that is 60" x 36" x 60" tall or as small as 36" x 36" Table top unit which is our Basic Emulsion model. Most units simply require 220V power source. US20170082371A1 - Integrated multi-chamber heat A one-piece heat exchanger manufactured using an additive manufacturing process is described. The heat exchanger includes a plurality of channels formed therein. At least some of the plurality of channels may be configured to provide structural support to the heat exchanger to reduce its weight. Different coolant media may be used in a first set and a second set of the plurality of channels to

[DOC]paraffin - University of Cambridge

 · Web viewDec 13, 2013 · The TSSHPS cooling season and heating season last around 90 days each. Using the above results, with emulsion reused 10 times, the annual benefit for a typical 12.5 MW capacity TSSHPS sub-system employing 500 m2 of plate heat exchanger surface for switching from manual cleaning to the paraffin coating method is estimated as 68,400 yr-1.Experimental study of the heat transfer characteristics of Apr 01, 2018 · A complete characterization of a paraffin emulsion was performed for a laminar flow inside a rectangular channel typical of plate heat exchangers. The present work reports an experimental study of the rheological and heat transfer characteristics of a 30 %wt paraffin emulsion that can be used as a two-phase secondary refrigerant.